Agilent Chemstation Software Manual
In this manual, the efficient use of the new data storage and retrieval functions in. The ChemStation User Interface during Data Review 30. Data Analysis:.
Autograph 3.3 Full Version. 4/23/2018 0 Comments Autograph is a complete dynamic environment for the secondary and college level mathematics classroom, offering. Autograph 3.3.0010 Full Version Autograph 3.3.0010 Serial & Crack Autograph 3.3.0010 Torrent. Your search for Autograph 3.3.0010 found zero results. Using Autograph from an iPad or Tablet PC wirelessly. Autograph 33 full version. Current version: Autograph 3.3.0010. Send us an update. 1,195 downloads Updated: Jun 30th, 2013 Trial. Autograph is a complete dynamic environment for the secondary and college level mathematics classroom, offering teachers and students alike the opportunity to bring the subject to life through the manipulation of dependant, selectable.
Lrosetti - For A.03.02 you'll need a computer running Win 3.x (we formerly used 486 and Pentium I CPUs). From what I know, you'll need an interface HPIB board which mounts to the rear panel of the 5890II and attaches to the GC board with a ribbon cable. That HPIB interface attaches to the HPIB board in the CPU using HPIB cable.
If you have an autosampler, its control box will also attach using a second HPIB cable. I just checked, I have G2070-90100 'Understanding your Chemstation' A.03 and G2170-90000 'Installing your Chemstation' A.03 but that's for 2D HPLC, but almost exactly the same.
Installation of the software is straightforward; there's really nothing in the manuals about which interface boards are needed, or where they go. As moino stated, the newer software versions and manuals are VERY similar; the main differences are that A.03 doesn't have the graphics of the later versions, and that the newer versions integrate the sequence recalibration events into the Sequence Table, where in A.03 that is saved as part of the Method (for example, 'replace' and 'average' are designated by numbers). I am not allowed by my company to 'sell' stuff like this, but I can answer your questions. Obratnij klapan chertezh. Consumer Products Guy wrote: lrosetti - For A.03.02 you'll need a computer running Win 3.x (we formerly used 486 and Pentium I CPUs).
From what I know, you'll need an interface HPIB board which mounts to the rear panel of the 5890II and attaches to the GC board with a ribbon cable. That HPIB interface attaches to the HPIB board in the CPU using HPIB cable. If you have an autosampler, its control box will also attach using a second HPIB cable. I just checked, I have G2070-90100 'Understanding your Chemstation' A.03 and G2170-90000 'Installing your Chemstation' A.03 but that's for 2D HPLC, but almost exactly the same.
Installation of the software is straightforward; there's really nothing in the manuals about which interface boards are needed, or where they go. As moino stated, the newer software versions and manuals are VERY similar; the main differences are that A.03 doesn't have the graphics of the later versions, and that the newer versions integrate the sequence recalibration events into the Sequence Table, where in A.03 that is saved as part of the Method (for example, 'replace' and 'average' are designated by numbers). I am not allowed by my company to 'sell' stuff like this, but I can answer your questions.
1.0 OBJECTIVE: To lay down the procedure for operation and calibration of High Performance Liquid Chromatograph. 2.0 INSTRUMENT IDENTIFICATION: Name of Instrument: High Performance Liquid Chromatography (Auto Sampler) Manufacturer: AGILENT Technologies 1260 series 3.0 GENERAL CLEANING: 3.1 Ensure that the power supply to the instrument is switched off and main Cord is removed from supply. 3.2 Clean the instrument with a clean dry cloth every day. A wet cloth dipped In dilute soap solution may be used occasionally. 3.3 Precaution must be taken to clean the instrument immediately with dry Cloth after wet cleaning. 4.0 PROCEDURE (OPERATION) 4.1 Ensure that the HPLC system is placed in a clean and dust free area.
4.2 Ensure that instrument have been connected to the main power unit. 4.3 Switch ‘ON’ the Computer. 4.4 Switch ‘ON’ the HPLC instrument. (Switch on the detector, column compartment, Pump and vacuum degasser simultaneously). 4.5 Ensure that the outlet from the detector dips into a waste bottle.
5.0 Start the Open Lab Chemistration by double-clicking the Short cute Open Lab Chemistration located on your desktop. 5.1 Click on Open Lab Chemistration online. 5.2 Then click on ‘on’ option. 5.3 Initialization process of HPLC system will be start which shows by yellow colour. 5.4 Green colour and ‘Ready’ indication will be appearing on screen after the Initialization process. 5.5 Click on set up- pump, feed the flow rate NMT 4%,% of solvent and then start the purging by rotating the purge wall in anticlockwise direction approx 10 minute. 5.6 Then ‘OFF’ the Purging by rotating the purge valve in clockwise direction.